The SCIEX clinical diagnostic portfolio is For In Vitro Diagnostic Use. Rx Only. Product(s) not available in all countries. For information on availability, please contact your local sales representative or refer to https://sciex.com/diagnostics. All other products are For Research Use Only. Not for use in Diagnostic Procedures.
Trademarks and/or registered trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners in the United States and/or certain other countries.
© 2020 DH Tech. Dev. Pte. Ltd.
Capillary electrophoresis sodium dodecyl sulfate (CE-SDS) is the only way to obtain automated, quantitative purity data (i.e. glycosylated vs non-glycosylated) on both intact and reduced monoclonal antibodies. It is quantitative, automated and fast.
CE-SDS data acquired by some technologies is regularly manipulated and enhanced. This may mask weaknesses in hardware and chemistries, and more importantly data quality. Only raw, unprocessed data can provide the confidence critical to both you and the regulatory for product submission and commercialization.
Only SCIEX CE technology uses circulating liquid temperature control to maximize data quality preventing the need for any data enhancement and manipulation. Additionally, our technology supports a wider range of method options.
[1]. Gel US Patent # US7,381,317. Automating the process of gel replacement is disclosed in US.
[2]. Patent # USRE37,606.
[3]. Chemistries referenced in USP Chapter <129>.
[4]. A Series of Collaborations between Various Pharmaceutical Companies and Regulatory Authorities Concerning the Analysis of Biomolecules Using Capillary Electrophoresis.” Chromatographia 2006, 64, September (No. 5/6).
[5]. The PA 800 Plus ensures requirements of 21CFR211.194 can be met by providing raw, unmanipulated data.
[6]. US Patent 5,198,091.
[7]. USP Chapter <129> Analytical Procedures for Recombinant Therapeutic Monoclonal Antibodies.
RUO-MKT18-7035-A
For research use only. Not for use in diagnostic procedures.
Technical Note: Assay of IgG Purity and Heterogeneity Using High-Resolution Sodium Doedecyl Sulfate Capillary Gel Electrophoresis
Technical Note: Automation of CE-SDS Sample Preparation for PA 800 plus IgG Purity/Heterogeneity Assays Using a Biomek 4000 Automation Workstation
Technical Note: Capillary Electrophoresis in Quality Control: PART I: Application for Therapeutic Proteins
Technical Note: Capillary Electrophoresis in Quality Control: PART II: CE-SDS: Method Development and Robustness
Flyer: Increase Method Robustness with SCIEX Low pH SDS Sample Buffer
In addition to quantitative data, automation, and full method development flexibility, the following benefits of SCIEX CE-SDS technology provide the critical confidence that you seek in your purity analysis from analytical development to QC.
The SCIEX CE-SDS proprietary replaceable gel technology[1], [2], is referenced in USP chapter <129> [3] and the application is recommended by a published intercompany collaboration.[4]
Patented circulating liquid cooling of the capillary[6] provides reproducible data that requires no enhancements nor manipulations. SCIEX CE-SDS always gives you secure raw data that better quantitates low MW species.[7]
Modular PDA or laser-induced fluorescence detection provides at least three orders of magnitude of impurity detection – 0.1% and 0.01% respectively.
The fastest separation without sacrificing resolution (12 min reduced, 18 min. non-reduced).
SCIEX CE-SDS offers detection with PDA or LIF and two validated chemistry kits.
Part # A10663
Component Quantity/Amount. Capillary, 50 μm I.D. bare-fused silica 2. SDS-MW Gel Buffer - proprietary formulation, pH 8, 0.2% SDS 140 mL. SDS-MW Sample Buffer - 100 mM Tris-HCl, pH 9.0, 1% SDS 50 mL. IgG Control Standard 1 mL. Internal Standard, 10 kDa protein, 5 mg/mL 0.4 mL. Acidic Wash Solution, 0.1 N HCl 100 mL. Basic Wash Solution, 0.1 N NaOH 100 mL.
Part # 390953. Component Quantity/Amount. Capillary, 50 μm I.D. bare-fused silica 2. SDS-MW Gel Buffer - proprietary formulation, pH 8, 0.2% SDS 140 mL. SDS-MW Sample Buffer - 100 mM Tris-HCl pH 9.0, 1%SDS 50 mL SDS-MW Size Standard (10 to 225 kDa, 16 mg/mL) 100 μL. Internal Standard, 10 kDa, protein 5mg/mL 0.4 mL. Acidic Wash Solution (0.1 N HCl) 100 mL. Basic Wash Solution (0.1N NaOH) 100 mL.
For ultimate sensitivity in impurity detection, upgrade to Laser Induced Fluorescence (LIF) detection. This upgrade (part # A59494) requires a PA 800 Plus or CESI 8000 Plus. This package consists of a durable solid-state laser and detector that can easily be switched with the PDA detection set-up.
The PA 800 Plus Pharmaceutical Analysis System is a robust analytical platform that provides characterization of product purity, charge heterogeneity and glycan analysis, to help you with the development and quality control of therapeutic proteins.
No need to inventory multiple cartridge types. One EZ-CE cartridge (part # A55625) for Purity, Rapid Charge Variant Analysis, and Fast Glycan Analysis
A new password has been sent to your email.
You have added a user.
Unfortunately the serial number you provided shows as inactive in our database. Would you like to submit the case anyway?
This serial number could not be found. Would you like to submit the case anyway?
Your password has been updated.
Your account is now created.
A verification link has been sent to your email.
A new password has been sent to your email.
Your insturment has been removed.
Your privacy settings are now updated.
Unfortunately the serial number you provided shows as inactive in our database. Please open a support case here if you require more assistance.
Software has already been registered to another instrument. Please check your AID and try again.
If you want to change the License Key to another instrument, please submit a new case.
Software has already been registered to the instrument selected.
Please check your instrument's software by going to the Instruments page and selecting the instrument in your "My Instruments" section. Here you will see a Software tab where you can view your instrument's software information.
You can also go to the Registered Software page to view software associated with your instrument(s).
If you are not finding what you are looking for, please submit a new case.