Engineered to deliver best-in-class quantitative analysis
The best just got better. The SCIEX Triple Quad 5500+ LC-MS/MS System – QTRAP Ready is equipped to conquer your laboratory’s most complex workflows and opportunities. With this LC-MS/MS system, you have the sensitivity and performance to meet analytical and regulatory demands for low-level trace detection with ease.
Triple Quad LC-MS/MS systems deliver superior quantitative results in a single injection workflow. When you activate the optional QTRAP functionality, your instrument acts as a linear ion trap (LIT). This allows you to acquire even more data from your sample without sacrificing the sensitivity or quality of your multiple reaction monitoring (MRM) analysis. The QTRAP technology incorporates additional scan types, such as MRM3 (MS/MS/MS), Enhanced Product Ion scans (EPI) and many more. The additional scans can run at the same time you are acquiring your MRM, without any impact on performance or quality of data.
The SCIEX 5500+ System is built on a legacy of cutting-edge engineering innovation. The quality and care are evident in the design of this mass spectrometer. The ion path contains multiple unique technological advances that will enable your laboratory to produce superior results.
Whether you are focusing on pharmaceutical drug discovery workflows, clinical research, food and beverage testing, complex environmental analysis, academic studies, or searching for answers from crucial forensic samples, the 5500+ system is equipped to handle the challenge.
The modular framework of the SCIEX 5500+ System enables additional component upgrades to enhance your data. The instrument is compatible with SelexION® differential mobility separation which delivers exceptional selectivity of isobaric compounds. If your workflow demands low flow rates, the OptiFlow® Turbo V™ Ion Source is the ideal technology to achieve your goals. Optimized for microflow chromatography, the OptiFlow ion source can further increase sensitivity, improve selectivity and reduce the consumption of solvents and other consumables.
Activating your license through a quick and easy process opens up your SCIEX Triple Quad to a world of possibilities with MS/MS confirmation, enhanced selectivity with MRM3, and other valuable scan types.
Turbo V Ion Source
Extraordinary robustness and superior performance across a wide range of compounds.
OptiFlow Turbo V Ion Source
Upgrade to the OptiFlow source for low-flow analysis. It is robust and simple to operate, with a flow-rate range of 1 -200 µL/min.
HED Detector and High Capacity CEM
Increased productivity with fast polarity switching of 5 msec enabling up to 6 orders of magnitude of linear dynamic range.
Scheduled MRM™ Algorithm Pro
With Analyst® software, maximize the number of MRM transitions to analyze more compounds in a single run without sacrificing precision.
SCIEX OS -Q Software
Increased MS quantitation productivity through streamlines data processing*
*Upgrade to SCIEX OS-Q Software to advance your data processing capabilities with additional qualitative analysis and processing functionality.
This mass spectrometer will exceed your expectations. It was engineered to address the things that matter to you most: robustness, sensitivity, maximum uptime, maximum productivity and a solid return on your investment.
Turbo V Ionization Source
Unique source architecture achieves high sensitivity over a wide range of flow rates.
OptiFlow Turbo V Ionization Source
Boost sensitivity with the OptiFlow Turbo V Ion source. It uses SteadySpray™ Probes to ensure consistency in low-flow applications.
QTRAP Ready
Activating your license through a quick and easy process opens up your SCIEX Triple Quad to a world of possibilities with MS/MS confirmation, enhanced selectivity with MRM3, and other valuable scan types.
SelexION Differential Mobility Separation
SelexION technology provides an extra level of selectivity so you can resolve difficult analytes and have more confidence in detection and quantification.
Analyst Software
Maximize the number of MRM transitions to analyze more compounds in a single run, without sacrificing precision.
SCIEX OS-MQ Software
The best way to process your data. Intelligent algorithms deliver a high degree of accuracy and certainty, without time-consuming manual data review.
A range of 5 to 1250 m/z encompasses many compound classes, enabling your organization to test for more analytes and explore your laboratory’s potential
Polarity Switching Time
A switching time of 5 msec in MRM and Scheduled MRM (sMRM) mode increases efficiency, by performing positive and negative ion analysis in the same acquisition, without compromising sensitivity
Dynamic Range
A dynamic range of up to six orders of magnitude encompasses analyte concentrations from low-level trace detection to those in high abundance
Detector Type
A high-energy dynode and multichannel electron multiplier provide you with the highest quality data for every sample acquisition
MRM Acquisition Rate
With an acquisition rate of 500 MRM/sec, even without using Scheduled MRM, the Triple Quad 5500+ QTRAP Ready system can analyze an extensive suite of compound
Scan Speed
At a scan speed of 12,000 Da/sec, this system detects the crucial analytes in your sample without missing a thing
Built-in Devices
A high-precision syringe pump makes it easier to optimize any new compounds you add to your portfolio of test offerings as your laboratory grows
With QTRAP technology you will still acquire the same high-quality MRM data for your low-level trace detection workflows.
Added Confirmation
The EPI scan is unique to QTRAP technology. Add a spectral fingerprint to the same MRM acquisition for greater confidence in your data.
See Through the Matrix
MRM3 is an effective scan solution for the quantification of analytes when high background and interferences make standard MRM quantification difficult.
Unrivaled QQQ Resolution
This scan is important in the acquisition of accurate molecular weight and to obtain both the value of the charge state and the accurate mass to charge ratio (m/z).
Full Scan Workflows
This scan type delivers a highly sensitive full scan for the detection of unknown analytes.
Whether for pharmaceutical analysis or food and environmental testing, the SCIEX Triple Quad 5500+ LC-MS/MS System – QTRAP Ready delivers the high-quality data you need to make decisions.
Regulated Bioanalysis
The SCIEX 5500+ System delivers quantitative and qualitative results for a broad range of diverse drug products. It achieves impeccable levels of sensitivity and selectivity helps to ensure proper dosage, efficacy, and safety.
Water Quality Testing
Acquire data that meets the low-level trace detection requirements of drinking and wastewater labs. Increase confidence with unrivaled confirmation scans like EPI for spectral library assurance.
Antibiotics in Food
Regulations determine the allowed levels of veterinary drugs in food products. These low-level residues are detected easily with MRM workflows. Activate QTRAP functionality to have even more confidence in your results.
Toxins in Food
This high-throughput workflow for mycotoxin testing is critical to achieving regulatory compliance. Use a combined MRM and QTRAP library workflow to achieve a new level of confidence in your data.
Pesticides
A variety of complex matrices are involved when testing for pesticides in fruit, vegetables, water, soil and other samples from emerging markets like cannabis. Quantify and confirm large suites of pesticides using these robust workflows.
Delivering high-quality, accurate data is one of the primary objectives of any laboratory. Invest in the best software to achieve your data quality goals. The SCIEX 5500+ System is powered by Analyst software for simple acquisition setup and SCIEX OS-MQ software for unrivaled, fast, accurate and efficient data review and processing.
Optimized Processing
SCIEX OS-MQ software introduces your laboratory to a new era of data processing. It was developed to increase your laboratory’s productivity while delivering accurate and high-quality results. The software platform focuses on getting your staff started easily so they can master it quickly.
Automatic Outlier Removal Algorithm
The algorithm automatically identifies responses that are outside of the calibration curve parameters. It calculates linear regressions and alerts you to any irregularities.
AutoPeak Integration Algorithm
Improve your workflow efficiency by delivering consistent integration across samples and batches and reducing the need for manual integration. The AutoPeak Integration Algorithm significantly speeds up your data review.
Compliance
Sample and data integrity are critical when delivering approved results. SCIEX OS-MQ software incorporates electronic audit trails, signatures and the security elements required for compliance with GxP and 21 CFR Part 11 Regulations.
Standard Addition
SCIEX OS-MQ software incorporates native standard addition, which allows it to perform those vital calculations alongside your integrated analysis.
Enhanced Filtering of Results
Filter your data your way. Unique filtering functionality and advanced flag rules make it easier than ever to interpret your data and focus on key results.
This serial number could not be found. Would you like to submit the case anyway?
Your password has been updated.
Your account is now created.
Your attachment has been successfully deleted.
A verification link has been sent to your email.
A new password has been sent to your email.
Your insturment has been removed.
Your privacy settings are now updated.
Thank you for your rating
File must be less than 20MB
You must be logged in.
Invalid token - please reload the page and retry.
This email is already associated with this instrument
Could not find request
Could not validate the key against any instrument requests
No instrument was found with that serial number
There is already a pending access request for this instrument.
You already have access to this instrument
You must be an instrument owner to add new users
This email is already associated with this instrument
This email address cannot be found. Please ask the user to create a SCIEX.com account.
The old password does not match our records.
Error creating user: That login already exists. Please choose a new login
Error creating user: Invalid Captcha
This email already exists. Please go to login and click Forgot Password.
You do not have permission to comment on this case
You must be an instrument owner to approve or reject users
This email is already associated with this instrument. You cannot deny this request - instead, remove them from the instrument.
You do not have permission to view this attachment
There was an error with your username, please email digitalhelp@sciex.com to restore your account.
Cannot find a user with that email address.
Your password was not recognized, you can request a new password above or email digitalhelp@sciex.com for help.
Your username was not recognized, please try again or email digitalhelp@sciex.com to resolve this.
There was an error with your username, please email digitalhelp@sciex.com to restore your account.
Cannot find enrollment
Could not find contacts
This licence is not a trial license.
Software has already been registered to another instrument. Please check your AID and try again. If you want to change the License Key to another instrument, please submit a new case.
Software has already been registered to the instrument selected. Please check your instrument's software by going to the Instruments page and selecting the instrument in your "My Instruments" section. Here you will see a Software tab where you can view your instrument's software information. You can also go to the Registered Software page to view software associated with your instrument(s). If you are not finding what you are looking for, please submit a new case.
Invalid License ID. Please try again.
You must be an instrument owner to remove users
You do not have permission to reopen this case
You do not have access to update this instrument
You do not have permissions to upload to this case