:true:
The Power of Precision
false
us
ZenoTOF 7600 system
X500R system
X500B system
View all
SelexION device
SCIEX 7500 system
SCIEX Triple Quad 6500+ system
SCIEX 5500+ system
QTRAP 6500+ system
QTRAP 4500 system
Citrine system
4500MD system
Jasper system
View all mass spectrometers
Echo MS system
Biologics Quant solution
Biotransform solution
MPX 2.0 High Throughput Multiplexing system
OptiFlow Quant solution
View all integrated solutions
BioPhase 8800 system
CESI 8000 Plus system
PA 800 Plus system
P/ACE MDQ Plus system
GenomeLab GeXP system
View all capillary electrophoresis
Advance your research with front-end instruments designed to help you realize the full power of your mass spectrometer. SCIEX has the broadest portfolio of ESI-MS front-ends that can facilitate various flow rates, sample requirements and sensitivities. No one else offers the entire range of analytical flow, microflow, nanoflow LC-MS and even ultra-low flow CESI-MS.
ExionLC 2.0 series
Micro HPLC columns
M5 MicroLC system
View All
Ultra-low Flow CESI-MS
View all front-end HPLC MS
Differential mobility spectrometry (DMS) and ion mobility spectrometry are analytical techniques used to separate ions based on their gas phase mobility. Multiple types of ion mobility devices exist, such as drift tubes, traveling wave, and high-field asymmetric waveform devices. Learn how you can separate yourself with Differential Ion Mobility.
The latest ion sources from SCIEX enable enhanced sensitivity and robustness with greater desolvation range across all MS platforms, from Triple Quad to QTRAP and QTOF.
Turbo V ion source
OptiFlow Turbo V ion source
OptiFlow Interface
View all ion sources
vMethod applications are pre-configured and verified LC-MS/MS methods that reduce the need for method development – significantly cutting the time, effort and money to deploy a new assay. Every vMethod provides method conditions, recommended sample prep, LC and MS conditions, and details for applicable MS/MS library databases for key applications.
AA45/20 1.0
aTRAQ
Illicit drugs
Acrylamide
Allergens
Antiobiotics/veterinary drugs
Cannabinoids
Illegal dyes
Melamine
Mycotoxins
Pesticides
Industrial chemicals (bisphenol)
Industrial chemicals (ethanolamines)
Pesticides (herbicides)
Pesticides (Polar)
Pharmaceutical and personal care products (PPCPs)
Peptide and protein bioanalysis
Routine biologics characterization
Benzodiazepines
Blood screening
Drugs of abuse
Etg and ets
Nicotine
THC-COOH
Urine screening
Explore vMethod applications
Software navigator tool
Free software trials
Software downloads
Software activation
Software support policy
Software support plans
Software feature request portal
Software partners
Analyst software
Analyst TF software
SCIEX OS software
Biologics Explorer software
Cliquid software
DiscoveryQuant software
Molecule Profiler software
OneOmics suite
View all software
High resolution and QTRAP libraries can dramatically enhance the quality of your analysis, giving you much improved confidence in your data. With a comprehensive library at your fingertips, you can easily create methods and process targeted and non-targeted screening data on your complex samples, faster and easier than ever before.
All in one library
SCIEX all-in-one HR-MS/MS library with NIST 2017
Antiobiotic Llbrary
Flurochemical library
Forensic library
Mycotoxin library
Natural products
Pesticide library
Wiley Libraries
Antibiotic library
Meta library
Explore the library selector tool
Boost the performance of your mass spectrometer and improve sensitivity, productivity, and data precision. iChemistry Solutions are the world's only reagents and consumables that are custom designed with your success in mind.
RNA 9000 Purity & Integrity kit
aTRAQ kit for amino acid analysis of hydrolysates
aTRAQ kit for amino acid analysis of physiological fluids
Automated protein digestion solution
Protein CE-SDS Purity Analysis kit
Chemical standard kits
CYP450 protein assay - human induction kit
CZE rapid charge variant analysis kit
BioPhase Fast Glycan Labeling and Analysis kit
iDQuant standards kit for pesticide analysis
Lipidyzer platform kits
roQ auEChERS extraction and dispersive kit
Ampliflex diene reagent
Ampliflex keto reagent
Cleavable ICAT reagent
iTRAQ reagent
mTRAQ reagent
View all consumables
QTOF – Quadrupole Time of Flight
QTRAP® – Triple Quad Linear Ion Trap
SWATH® – Data Independent Acquisition
SelexION® – Differential Mobility Separation
MicroLC – Microflow Chromatography
Ultra Low-Flow CESI-MS Technology
iCIEF-MS Technology
Nominal Mass LC-MS-MS
Acoustic Ejection Mass Spectrometry
View All Technology
From substantiating new discoveries through to end-to-end validated workflows for high-throughput biomarker testing in the clinic, thousands of scientists worldwide depend upon mass spec innovation from SCIEX to advance their work in the fields of clinical, research, omics and diagnostics.
Clinical research (coming soon!)
Clinical diagnostics (coming soon!)
View All Clinical
PFAS
Pesticides & herbicides
PPCP
Disinfection by-products
Soil and biota
Ethanolamine
Synthetic polymers
Exposome
Suspect screening
Nanomaterials
View All Environmental Testing
How do you protect your reputation and meet today’s global food safety standards? Whether you are a commercial lab or a food manufacturer, the quality of your food testing data is vital to your business. SCIEX solutions help you meet maximum residue limits (MRLs) with high-quality data that you can genuinely count upon. With a portfolio of applications, your lab can quickly and easily react to diverse market needs.
Pesticide Testing
Mycotoxins Testing
Antibiotics Testing
Potency Testing
Mycotoxin Testing
Terpenes Profiling
Meat Speciation Testing
Food Fraud Analysis
Food Adulterant Testing
Food Dye Testing
Food Omics
Allergen Testing
Ingredient Authenticity & Profiling Analysis
Packaging & Food Contact Substance Analysis
View All Food and Beverage Testing
How do you ensure the integrity of your results in an industry that is never constant? By accurately detecting even the smallest compound angles you can deliver evidence that stands. SCIEX forensic analysis solutions deliver fast, highly accurate data across a multitude of compounds and biomarkers, from the known to the new and novel.
Forensic toxicology (coming soon!)
Homeland security (coming soon!)
Cannabis and hemp potency testing
Doping control (coming soon!)
View All Forensics Testing
Discovery Proteomics
Next-Generation Proteomics
Targeted Proteomics
Discovery Lipidomics
Targeted Lipidomics
Untargeted Metabolomics
Targeted Metabolomics
Metabolic flux analysis
Gene Expression Analysis
DNA Sequencing
Genotyping and SNP Analysis
STR Analysis
AFLPs
View All Life Science Research
Transform the capacity and capability of your biologics pipeline with complete end-to-end solutions that make your lab more productive, and more successful. With a longstanding track record in pharma discovery, development and manufacturing, our unparalleled application knowledge with best-in-class hardware, software and support all integrate to revolutionize your lab.
Small Molecule Quant
Peptide Protein Quant
Oligonucleotide Quant
Comprehensive Metabolite Identification
Biotherapeutic Catabolism
Native Mode Analysis
High Throughput ADME
Intact Protein Analysis
Peptide Mapping
Protein Glycosylation/Microhetrogeneity
Purity/Heterogeneity Analysis
Identity/Charge Heterogeneity
Host Cell Proteins
Capsid Analysis
Nucleic Acid and Plasmid Analysis
SNP Analysis
Gene Expression Profiling
View All Pharma and Biopharma
Citrine Mass Spec
4500MD Mass Spec
Jasper HPLC System
Analyst MD Software
Cliquid MD Software
MultiQuant MD Software
ClearCore MD software
Clinical Mass Spec Operators
Clinical Method Developers
Clinical Lab Managers
View All Diagnostics
The SCIEX Now Learning Hub offers the most diverse and flexible learning options available, with best-inclass content that helps you to get the most out of your instrument and take your lab to the next level. Available personalized learning paths based on the latest memory science ensure better knowledge retention, and automated onboarding and enrollment means you’ll get up and running faster.
SCIEX Now Learning Hub offers the most diverse and flexible learning options available, with best-in-class content that helps you to get the most out of your instrument and take your lab to the next level. Available personalized learning paths based on the latest memory science ensure better knowledge retention, and automated onboarding and enrollment means you’ll get up and running faster.
SCIEX Learning Manager provides you with the infrastructure to assign, monitor and report on your staff's competency through a single digital platform. Effectively manage the training process for new hires, ensure continuous staff development and access information with a single log-in to your SCIEX account.
You can browse, filter, or search our extensive list of training offerings. Choose from over 100 self-paced eLearnings or search for an instructor-led course near you. Once you select the course you want to take, you will be directed to Learning Hub for enrollment (login required).
SCIEX Now Online is the Everything, Anytime destination for all your SCIEX support needs. You can keep track of activities that matter most to you and manage your lab in the most efficient way possible. Extensive self-help resources like our deep Knowledge Base, enable you to solve many problems on your own. SCIEX Now is available 24/7 and your new SCIEX instruments are automatically added to your profile when you purchase.
Support Cases
SCIEX Now Learning Hub
Instruments
Manage My Instruments
Registered Software
Activate Software
Resource Library
My Notifications
Request Support
Course Catalog
Software Downloads
SCIEX Store
SCIEX Now New Feature Request
Software New Feature Request
Online ordering solutions
Log In
Don't have an account? Create One
Visit your SCIEX Now™ Dashboard
No one understands your needs and can support your systems better than we can. Our mission is to help you be successful, whether it's to repair your instrument, assist with your workflows, or help you maximize productivity in your lab. Whatever your challenge, global SCIEX Service and Support personnel are subject matter experts who are focused on mass spec and capillary electrophoresis, so you'll be able to achieve your scientific goals quickly and efficiently.
LC-MS Service Plans
Protect Plus Suite for Your New LC-MS
CE Service Plans
Clinical Service Plan
StatusScope Remote Monitoring
Laboratory Optimization Services
Compliance Consultancy
Qualification and Validation
On-Site Applications Support
Professional Relocation Services
View All Instrument Service & Support
Software Accelerator Program
Software Support Plans
Software Support Policy
Premium Access Content
View All Support Tools
SCIEX Now Learning Hub is much more than online courses. For the most comprehensive option, you can select Success Programs: personalized, blended online and in-person courses. If your needs are met by a visit from one of our training experts, you can choose multiple Onsite Training days to get your lab running. Visit a SCIEX training center in North America, Europe or Asia for intensive classroom and laboratory training. And your online courses are available any time, from anywhere, right here.
Login to SCIEX Now Learning Hub
Success Programs at Your Site
Online Course Catalog
Clinical Knowledge Center
Application Scientist Training at Your Site
China
Europe
German CE Courses
India
Japan
Korea
North America
UK
Visit all Training
If you have CE, LC or mass spec questions, then SCIEX has the answers. SCIEX support is the single destination for your system questions. We aim to fully assist you with virtually every application of our instruments, helping you to get the most out of your lab resources and assets.
Frequently Asked Questions
View All Request Support
As a life science researcher, you need the tools and support to help you create the scientific foundation in pursuit of expanding the knowledge-base, whether it is understanding fundamental biology, finding new biomarkers, discovering ways to improve our quality of life, or other areas of research. We are committed to the same goals and put the very same dedication into our work to help you address your most significant research challenges.
Academic Partnership Program
Academic Partners
View All Partnership Programs
Regulatory compliance is as paramount for us as it is for you. That’s why we have made it easy for you to freely reference all relevant technical and product regulatory documents. To give you confidence that, with SCIEX, you will fully comply with legislation, adhere to your laboratory protocol and meet industry standards.
Declaration of Conformance
Safety Data Sheets
Certificates of Analysis
View All Regulatory Documents
SCIEX supplies extensive documentation to help you prepare for, use, and maintain your SCIEX hardware and software products, and we update this documentation regularly. On the Customer Documents page, you can search for and download the latest documents for your product.
Customer Documents
Join the SCIEX community today to interact with your peers, share and exchange ideas, develop your knowledge, stay up-to-date with the latest products, post insights and questions, comment on others and receive support. This community is designed to help you, our customers, move science forward and get the answers you need. We’re committed to engaging with and listening to you, to create the best customer experience possible and to contribute to the success of your work.
Biopharma
Clinical
Environmental / Industrial
Food and Beverage
Forensics
Life Science Research
Pharma
Technology
Knowledge Base Articles
SCIEX Now Feature Requests
Software Feature Requests
Newsletter Archive
Featured Content
FAQs
View All Community
About SCIEX
About Danaher
Customer Profiles
Our History
Our favorite papers
Meet our executives
Career opportunities
Contact us
Press releases
In the news
Awards
You've got questions. We've got experts who can help. Contact us to find out more, talk to a specialist, explore our solutions or get expert support.
Talk to a specialist
Request more information
Request a quote
Request support
SCIEX success network
Frequently asked questions
SCIEX community
Request hosted catalog
Request punchout
Global public relations
508-782-9484
Country/Region Canada Mexico United States
Country/Region Argentina Brazil Chile Colombia Costa Rica Ecuador El Salvador Guatemala Peru Uruguay Venezuela
Country/Region Germany Albania Austria Belgium Bosnia and Herzegovina Bulgaria Croatia Cyprus Czech Republic Denmark Estonia Finland France Germany Greece Hungary Ireland Italy Latvia Lithuania Luxembourg Macedonia Montenegro Netherlands Norway Poland Portugal Romania Serbia Slovakia Slovenia Spain Sweden Switzerland United Kingdom
Country/Region Bangladesh Brunei Darussalam Cambodia 中国 Hong Kong India Indonesia 日本 한국 Singapore Sri Lanka Taiwan Thailand Viet Nam
Country/Region Bahrain Iran Iraq Israel Jordan Kuwait Lebanon Oman Pakistan Palestine Qatar Saudi Arabia Syria Turkey United Arab Emirates Yemen
Country/Region Algeria Angola Botswana Burundi Egypt Ethiopia Kenya Liberia Libya Morocco Rwanda South Africa Tunisia Uganda United Republic of Tanzania Zambia Zimbabwe
Country/Region Armenia Azerbaijan Belarus Georgia Kazakhstan Kyrgyzstan Moldova Russia Tajikistan Turkmenistan Ukraine Uzbekistan
Country/Region Australia Micronesia New Zealand
AB Sciex is doing business as SCIEX. © 2010-2018 AB Sciex. The trademarks mentioned herein are the property of the AB Sciex Pte. Ltd. or their respective owners. AB SCIEX™ is being used under license. Beckman Coulter® is being used under license. Product(s) may not be available in all countries. For information on availability, please contact your local representative. For research use only. Not for use in diagnostic procedures.
Download tech note (PDF)
Using the SCIEX Triple Quad™ 7500 LC-MS/MS System – QTRAP® Ready
Catherine S. Lane1, Bart Van Puyvelde2, Katleen Van Uytfanghe2, Andrea-Bhangu-Uhlmann3, Maarten Dhaenens2 1SCIEX, UK, 2Ghent University, Belgium, 3PolyQuant GmbH, Germany
Targeted peptide quantification assay has been developed to investigate the potential use of nasopharyngeal swabs in a saline matrix for the quantification of SARS-CoV-2 coronavirus proteins using LC-MS/MS. The gains in sensitivity attained by moving the assay onto the next-generation SCIEX Triple Quad 7500 LC-MS/MS System and reducing matrix effects by changing swab storage medium were characterized.
Research into the epidemiology of the SARS-CoV-2 virus necessitates wide-scale sampling of large populations. The majority of assays for viral testing target detection of the SARS-CoV-2 nucleic acid (RNA), however, antigen tests targeting viral protein are generating interest globally amongst researchers in this field. The use of mass spectrometry for the detection of proteins from biological matrices is well established. However, the desire for increased sensitivity is always a goal in any quantitative assay and, thus far, in this case, mass spectrometry has struggled to match the sensitivities achieved by the more widely used reverse-transcriptase polymerase chain reaction (RT-PCR)-based tests. Here, the sensitivity of peptide detection in swab matrices is explored in order to compare with the sensitivity typical in RNA based detection strategies.
The SCIEX 7500 System shows significant gains in sensitivity relative to the previous generation of instruments because of improvements in both the generation and the sampling of ions.1,2 Furthermore, the preservation medium utilized for the collection of swab samples can have a considerable impact on the sensitivity of the LC-MS/MS assay.3 Here, building on the method developed previously4, the MRM assay is applied to the analysis of nasopharyngeal swab samples preserved in eSwab medium (saline matrix), using the SCIEX 7500 System to quantify the increased sensitivity (Figure 1).
Figure 1. Quantification of NCAP peptide. Calibration line and extracted ion chromatograms (XICs) for KQQTVTLLPAADLDDFSK from SARS-CoV-2 NCAP protein spiked into nasopharyngeal swab samples (XICs shown are for 2.5 ng and 10 ng protein in 250 µL swab samples).
The work described here was carried out as part of the Cov-MS consortium3, a community group established by Maarten Dhaenens at Ghent University, Belgium, with the aim of increasing applicability, accessibility, sensitivity and robustness of the detection of SARS-CoV-2 by electrospray mass spectrometry, thus increasing awareness of the technique as an important research tool. The consortium is made up of both academic laboratories and industrial partners. As such, the samples analyzed here were also examined by multiple other collaborators.
Sample preparation: Additional method optimization and retention time scheduling was performed using trypsin-digested spike glycoprotein (P0DTC2, SPIKE_SARS2), nucleocapsid protein (P0DTC9, NCAP_SARS2) and QconCAT standard (PolyQuant), prepared as previously described.4
Dilution series were prepared by spiking the recombinant proteins (0, 0.05, 0.1, 0.5, 1, 5, 10, 50, 100 ng) into 250 µL pooled nasopharyngeal swabs from 3 volunteers in eSwab matrix. To all samples, 120 ng QconCAT was added. Samples were vortexed with ice-cold acetone (1750 µL), then centrifuged at 16,000g for 10 mins at 0 °C. Acetone was removed, and pellets were left to dry. Dried pellets were re-suspended in 250 µL of 5% acetonitrile in 50 mM TEAB, then 50 µL of 0.1µg/µL Trypsin/LysC was added. Samples were vortexed, centrifuged and incubated for 15 minutes at 37 °C. 50 µL of each sample was removed and lyophilized. Samples were resuspended in 50 µL of 0.1% formic acid in 5% acetonitrile and 5 µL was injected per analysis. A sample containing approximately 2.5 ng recombinant protein in 250 µL eSwab was prepared by mixing equal volumes of the 5 ng and 0.05 ng samples.
Chromatography: Peptide separation was performed using an ExionLC™ system and a Phenomenex Luna Omega Polar C18 column (2.1 x 50 mm, 1.6 µm). Flow rate of 0.6 mL/min was used for fast analysis times. Gradient is described in Table 1. Column temperature was 40 °C.
Table 1. Gradient for peptide separation.
Mass spectrometry: MRM analysis of the selected peptides was performed using a SCIEX 7500 System operating in positive ionization mode. Source conditions were ISV 2000 V, GS1 40, GS2 70, TEM 450°C and CUR 40. Scheduled MRM™ Algorithm was used for optimum detection efficiency, using retention time tolerance of 15 sec and a target scan time of 0.4 sec. MRM transitions targeting QconCAT and histone peptides were assigned dwell times of 5 msec. Optimized MRM transitions and compound dependent parameters are shown in Table 2.
Data processing: MRM transition and voltage optimization was performed using Skyline software. Source optimization was performed using SCIEX OS-Q Software. Data were processed using SCIEX OS-Q Software.
In this work, the MRM assay previously optimized on the SCIEX Triple Quad 5500+ LC-MS/MS System – QTRAP Ready4, targeting peptides from SPIKE and NCAP, was transferred to the SCIEX 7500 System to determine the increased sensitivity. Using the digested recombinant proteins and Skyline software, collision energy values optimized on the SCIEX 5500+ System were re-evaluated on the SCIEX 7500 System and found to be very similar (within 4 V). Stable-isotope labeled standards are routinely used in MS-based assays to increase robustness, allow absolute quantification, and enable normalization across multiple instruments and laboratories. The Cov-MS QconCAT construct includes seventeen 15N-labeled SPIKE and NCAP peptides, separated by their native amino acids and one peptide from each of four human core histone proteins that were added to serve as markers for swab sampling quality. It was surmised that efficient swab sampling should cause superficial tissue damage, resulting in the presence of nuclear histone proteins in the swab sample. If the histone peptides are absent from a sample, this could potentially indicate poor sampling efficiency. MRM transitions were optimized for histone peptides using the QconCAT standard and Skyline software.
The final MRM assay involved two MRMs per peptide (one MRM each for native and heavy-isotope-labeled peptides) for each of ten of the best-responding SPIKE and NCAP peptides and three histone peptides (Table 2). One SPIKE peptide, FLPFQQFGR, found to respond well elsewhere, was included in the assay despite not being present in the QconCAT standard. If this peptide were to be retained for future SARS-CoV-2 antigen analyses, its incorporation into the QconCAT structure would be desirable. Retention times were scheduled, and dwell times fixed at 5 msec for heavy-isotope-labeled and histone peptides, to allow the bulk of the cycle time to be assigned to native SPIKE and NCAP peptides.
Wide-scale detection of SARS-CoV-2 would necessarily require the ability to measure very large numbers of samples per day. In the interest of throughput, the LC column and gradient used for peptide separation was shortened compared to previous work.4 A 50-mm column with 1.6-µm particle size was selected, and the total analysis time shortened to 4.5 min (from 7 min). The shortened analysis time provided good separation of target peptides (Figure 2).
Table 2. Optimized MRM transitions for quantification of key SARS-CoV-2 coronavirus proteins, SPIKE and NCAP, on the SCIEX 7500 System.
Figure 2. Chromatographic separation of 10 SARS-CoV-2 peptides (upper panel) and 3 histone peptides (lower panel) from a pooled nasopharyngeal swab sample in eSwab matrix spiked with recombinant SARS-CoV-2 proteins and QconCAT (100 ng each of SPIKE and NCAP, 120 ng QconCAT in 250 µL swab sample). Excellent separation of target peptides was maintained despite decreasing the time of the analysis from 7 min to 4.5 min.
The preservation medium used for the collection of swab samples can have considerable impact on the sensitivity of the LC-MS/MS assay.3 Previously4, samples were analyzed in UTM viral transport medium. However, UTM contains proteins, antibiotics and antimycotics5, which cause high background signal and ion suppression in the assay. ESwab is a salt-based medium without the protein and antibiotic content.6
While ion suppression would still be expected from the eSwab background, no protein-based interference would be anticipated. With this in mind, dilution series were prepared by spiking recombinant proteins and QconCAT into pooled nasopharyngeal swabs from volunteers in eSwab matrix. Samples were subjected to acetone precipitation and protein pellets were resuspended and digested with Trypsin/LysC. Samples were analyzed on the SCIEX 7500 System using the optimized MRM assay.
Sensitivity increases of 2 to 20 fold were observed for the SCIEX 7500 System analysis of peptides from SARS-CoV-2 proteins in nasopharyngeal swabs stored in eSwab, when compared with analysis of similar samples in UTM background on the SCIEX 5500+ System4 (Table 3). Lower limits of detection and quantification (LLOD and LLOQ) are outlined in Table 3. Examples of the MRM signal observed from SARS-CoV-2 peptides in eSwab matrix are shown in Figure 3. Calibration curves for all peptides are shown in Figure 4. The typical bioanalytical criteria for determination of LLOQ are accuracy of ±20%, precision of <20% at LLOQ and <15% across the calibration curve.
An example of how use of the QconCAT internal standard can increase assay robustness during sample preparation is shown in Figure 5 and Table 4.
Table 3. Lower limits of detection and quantification obtained for 10 peptides. The LLODs ranged from 0.07 to 0.44 fmol/µL in pooled nasopharyngeal swabs in eSwab matrix on the SCIEX 7500 System. Significant improvements in detection limits were observed from the previous work, by switching to using the eSwab medium and the higher sensitivity instrument.
Figure 3. Example peptide data. Signal from four SARS-CoV-2 peptides for the low end of the dilution series.
Figure 4. Calibration curves for ten SARS-CoV-2 peptides in eSwab matrix. Excellent linearity was observed for all peptides with r2 values between 0.9940 and 0.9997.
Figure 5. Use of a QconCAT internal standard for increased assay robustness during sample preparation. The upper pane shows variation in MRM peak area for 3 histone peptides in each of 10 samples, each analyzed three times (30 consecutive analyses). The lower pane shows variation in MRM peak area ratio (analyte peak area / internal standard peak area) for the same analyses. For each peptide, the use of the QconCAT stable-isotope-labeled standard substantially reduces the %CV for the 30 analyses (Table 4).
Table 4. Variation in %CV for three histone peptides in 10 samples with and without use of the QconCAT internal standard.
While the work described here is one step further towards a LC-MS/MS assay for the measurement of viral proteins in swab samples, there is still more work to be done. Sensitivities for current RT-PCR tests are measured in cycle threshold (Ct) values. While the same sample can give different Ct values on different RT-PCR assays7 a lower Ct value indicates a higher level of virus. As the amount of virus decreases, Ct values rise gradually. Because Ct is only a semi-quantitative (and variable) indicator of the amount of virus present, the conversion from Ct to amount of viral protein in a swab sample is not straightforward. Nevertheless, recently Van Puyvelde et al.3 estimated a Ct value of 20 to be approximately equivalent to 1.3 fmol NCAP in 10 µL swab sample, and Ct 25 to be equivalent to 41 amol NCAP in 10 µL swab sample. If a 32-fold concentration factor were applied at the sample preparation stage, then 1.3 fmol and 41 amol would correspond to Ct 25 and 30, respectively. These limits of detection in matrix are achievable using high-end triple quadrupole instruments8 but, for the highest possible levels of sensitivity, optimization of sample preparation will be key. Potential areas for improvement include the substitution of eSwab matrix for one with lower salt content, the use of other sample clean-up approaches and the use of sample enrichment strategies. One such strategy, SISCAPA (Stable Isotope Standards and Capture by Anti-Peptide Antibodies), has previously been used to improve the performance of mass spectrometry for measurement of pre-selected protein targets.9
Here, the targeted peptide quantification assay described previously4 has been refined and developed to investigate the potential use of nasopharyngeal swabs in a saline matrix for the quantification of SARS-CoV-2 coronavirus proteins. Further optimization included the addition of a QconCAT stable isotope labeled standard for increased robustness, swab sampling efficiency, inter-laboratory comparison and reduction in analysis time for use in high-throughput environments. The gains in sensitivity attained by moving the assay onto the SCIEX 7500 System, and by reducing matrix effects by changing swab storage medium, could be further increased by use of sample enrichment and clean-up strategies, such as SISCAPA9 or SPE, or by moving to a more MS-friendly swab storage matrix.
This assay has not been validated on real test samples and should not be used for patient testing. More work is required to translate this peptide quantification assay into a useful assay for determination of viral particle numbers.