The revolutionary sensitivity, speed, and performance delivered through these technology enhancements enable you to see it all, from low mass to high mass compounds, in positive or negative polarity – in a single injection, with high sensitivity, reliability, and confidence.

  • Superior signal-to-noise and LOQ for the widest scope of chemical compounds in the most challenging matrices
  • Up to 6 orders of linear dynamic range for an enhanced breadth of applications
  • Increased throughput with polarity switching speeds of 5 msec
  • No compromise in mass range with a 2000 m/z upper mass limit
  • Scan speeds of up to 12,000 Da/second for optimized UHPLC strategies
  • Compatible with SelexION+ differential mobility spectometry
  • Enhanced ion transmission for added selectivity without compromising LOQs

The Triple Quad 6500+ system delivers revolutionary sensitivity, speed, and performance for your most challenging methods.

Key features of the system

Mass range

Triple quadrupole: 5 – 2,000 Da; linear ion trap: 50 – 2,000 Da

Flexible ionization options

Options include OptiFlow Turbo V Electrospray ionization (ESI) and heated nebulizer ionization probes.

Selective, robust and powerful ion separation

Optional SelexION+ differential mobility spectrometry

Detector type

IonDrive High Energy Detector+

Polarity switching

5 msec in MRM and Scheduled MRM modes

Get more information

More ions with IonDrive technology

Enhancements for the 6500+ series

The production of more ions with the IonDrive Turbo V source is just one of the enhancements you will see with the Triple Quad 6500+ system. Also added is the ability to capture and transmit more ions with the unique IonDrive QJet guide and greater detection with the new IonDrive High Energy Detector+.

IonDrive Turbo V source

The new design of the legendary Turbo V source increases ion production by using enhanced gas flow dynamics and optimized heater configuration to improve reliability, reproducibility, and robustness.

IonDrive QJet guide

With its dual-stage design, the IonDrive QJet guide improves sensitivity and ion capture rate while focusing ions more efficiently than funnel approaches.

IonDrive high energy detector+

Pulse counting fundamentals achieve ultra sensitivity at the lower end, while increasing linearity at high count rates. The result is the collection of more ions across a broader dynamic range.

SelexION+ differential mobility spectrometry

Ideal development suite for applications requiring the separation of isobaric species, isolation of challenging co-eluting contaminants and reduction of high background noise.