AB Sciex is doing business as SCIEX. © 2010-2019 AB Sciex. The trademarks mentioned herein are the property of the AB Sciex Pte. Ltd. or their respective owners. AB SCIEX™ is being used under license. Beckman Coulter® is being used under license. Product(s) may not be available in all countries. For information on availability, please contact your local representative. For research use only. Not for use in diagnostic procedures.

SCIEX accurate mass QTOF technology can boost productivity in your lab. But better performance should only come with simplicity. Analyst TF Software is the core engine of SCIEX high resolution, accurate mass TripleTOF systems. It is the software your lab needs to enjoy their unmatched speed, robustness and accuracy. All with ease-of-use and flexibility to please both novice and expert users.
Analyst TF Software functionalities include:

Analyst TF Software delivers both full-system integration and enables you to construct your LC-MS/MS methods, all from a single point of control. Additionally, Analyst TF Software is the central integration point for further add-on packages such as MasterView™ Software, MetabolitePilot™ Software, MultiQuant™ Software, SWATH® Acquisition, and ProteinPilot™ Software, providing you with additional analysis options.
Spend more time understanding your data and less time running samples and maximize your laboratory’s quantitative performance and accuracy. Easily schedule up to 4000 individual MRM transitions within a single run with Scheduled MRM™ Pro.
Forget hunting and scrolling through each chromatogram to view your peaks. With the Integration Quality™ Index, you get all the goodies, with less effort. You can also obtain quantitative and structural information in a single injection using the Information-Dependent Acquisition (IDA) mode, through the automatic switching between MS and MS/MS scanning modes.
Don't wait to uncover underlying peaks. The Dynamic Background Subtraction™ algorithm (DBS) allows you to subtract background ions and reveal underlying components dynamically throughout a run.
Analyst TF Software makes compliance less cumbersome, incorporating the comprehensive security and audit trails that provide the documentation and electronic records required for GLP compliance. Maintain your laboratory standards by relying on Analyst TF Software, designed to support 21 CFR Part 11 compliance regulations.
Whatever your needs, SCIEX high resolution accurate mass QTOF solutions have been designed to deliver high performance qualitative and quantitative analyses across a wide range of application areas. Our TripleTOF systems have become known for delivering best-in-class flexibility, sensitivity and linear dynamic range.
The impressive TripleTOF 6600 system offers the highest sensitivity, linear dynamic range and scan speed to help you dig deeper into complex samples. Power your advanced workflows with more complete data, signature workflow flexibility, and enhanced quantitation to bring your lab to a new level.
The TripleTOF 5600+ System combines SCIEX Triple Quad technology with the Accelerator TOF Analyzer, to deliver nominal mass and accurate mass benefits in a single platform. It uniquely integrates comprehensive, qualitative exploration, rapid profiling, and high-resolution quantitation workflows.
RUO-MKT-18-2836-B
For research use only. Not for use in diagnostic procedures.
Advanced system control: Analyst Software is an integral part of any SCIEX Mass Spectrometer system, delivering both full-system integration and a single point of control for a range of HPLC components, automated sample preparation systems, and ion sources. On top of this, Analyst Software acts as a central integration point for add-on software packages like; MasterView Software, MetabolitePilot Software, MultiQuant Software, SWATH® Software and ProteinPilot Software that provide advanced features for advanced screening analysis, metabolite identification, MRM quantitation, SWATH® data processing, and and protein identification, enhancing ease of use, productivity, and throughput.
Advanced features for faster results: Automatic tuning and calibration save you time and maximize your mass spectrometer's performance. Automated method optimization speeds method development. For increased structural information, Information-Dependent Acquisition (IDA) mode enables unattended, automatic switching between MS and MS/MS scanning modes during data acquisition. The quantitation wizard quickly creates new quantitation methods to enhance the speed of processing. Finally, Analyst Software provides numerous features for data review and analysis including queries, metric plots, configurable results tables, and customizable, Microsoft Word-based report templates.
Perfect for the regulated lab: Industry-leading validation services in conjunction with comprehensive security and centralized audit-trail features provide documentation and electronic records for easier GLP compliance. These and many other features are why more LC/MS-based labs adhering to 21 CFR Part 11 rely on Analyst Software.
RUO-MKT-18-2836-A
| Title | Date |
|---|---|
| CloudConnect Auto Uploader | 09/12/2017 |
| Tutorial: Analyst Device Driver 1.2 | 02/28/2017 |
| AnalystTF 1.7.1 Software Installation Guide | 05/01/2015 |
| Peptide Mapping Workflow for the Rapid Characterization of Biologics | 03/05/2015 |
| AnalystTF 1.7 Software Installation Guide | 08/01/2014 |
| Analyst TF 1.7 Software SelexION Technology User Guide | 07/01/2014 |
| AnalystTF 1.5 Sofware Installation Guide | 06/01/2012 |
| AnalystTF 1.6 Software Installation Guide | 06/01/2012 |
| AnalystTF 1.5.1 Software Installation Guide | 04/01/2011 |
A new password has been sent to your email.
You have added a user.
This serial number could not be found. Would you like to submit the case anyway?
Your password has been updated.
Your account is now created.
A verification link has been sent to your email.
A new password has been sent to your email.
Your insturment has been removed.
Your privacy settings are now updated.
Software has already been registered to another instrument. Please check your AID and try again.
If you want to change the License Key to another instrument, please submit a new case.
Software has already been registered to the instrument selected.
Please check your instrument's software by going to the Instruments page and selecting the instrument in your "My Instruments" section. Here you will see a Software tab where you can view your instrument's software information.
You can also go to the Registered Software page to view software associated with your instrument(s).
If you are not finding what you are looking for, please submit a new case.