LeadScape® 3.0 Analyze software for the Echo® MS system
Mackenzie Pearson1 and Han Wang2
1SCIEX, USA; 2SCIEX, Singapore
High-throughput ADME workflows rely on fast turnaround times as these measurements help make informed decisions on potential drug candidates in drug discovery. The Echo MS system with LeadScape Analyze software combines speed of analysis with ease of use to run a 384 well plate in 11 minutes and enable a 50,000 compound campaign to be completed in as low as 24 hours which translates to up to a 14x TAT improvement when compared to LC-MS/MS analysis.
One of the key steps in pharmaceutical drug discovery is the analysis and optimization of lead drug candidates through precision data that speaks to their in-vitro and in-vivo bioavailability, metabolism and pharmacological effects. Absorption, distribution, metabolism and excretion (ADME) groups analyze these pharmacokinetic properties and often utilize LC-MS/MS strategies to properly characterize safety and efficacy of these drug candidates to make informed decisions that influence preclinical assessments and clinical phases.
Advances in high throughput screening and medicinal chemistry along with requirement to bring ADME studies earlier into development cycle have necessitated development of high throughput approaches in ADME labs. Researchers require increased efficiency, sensitive and reproducible data to deliver unequivocal results with fast turnaround times for large sample sets. With Acoustic Ejection Mass Spectrometry (AEMS) employed on the Echo® MS system, sample volumes as low as 2.5 nL are delivered by an Open Port Interface (OPI) that is connected to the SCIEX Triple Quad 6500+ mass spectrometer.1 A carrier solvent is used to deliver the sample into the electrospray ionization OptiFlow Turbo V ion source to analyze samples at rates as fast as 1 second per sample with minimal carryover.
However, method optimization and batch curation can often be a bottleneck when analyzing hundreds to thousands of compounds. Figure 1 outlines the optimization and analysis workflow implemented to improve turnaround time whilst reducing number of manual steps (as low as 5 clicks per batch) and amount of sample consumption (as low as 2.5 nL per sample) in the lab. First, the optimization of compound parameters is performed on the SCIEX Triple Quad 6500+ mass spectrometer partnered with an ExionLC system using DiscoveryQuant software. Then, LeadScape Analyze software, coupled with the Echo® MS system, accelerates the workflow by importing MRM parameters from an existing LIMS system (DQ database) into SCIEX OS software. Here, sample batches are easily generated and submitted to SCIEX OS software for data acquisition and data processing. Here, using LeadScape Analyze software with the Echo® MS system, a 384 well plate was analyzed in 11 min compared to 160 min needed using DiscoveryQuant software with LC-MS/MS.