The SCIEX clinical diagnostic portfolio is For In Vitro Diagnostic Use. Rx Only. Product(s) not available in all countries. For information on availability, please contact your local sales representative or refer to https://sciex.com/diagnostics. All other products are For Research Use Only. Not for use in Diagnostic Procedures.
Trademarks and/or registered trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners in the United States and/or certain other countries.
© 2019 DH Tech. Dev. Pte. Ltd.
Knowledge Base is your tool to finding answers about common questions. Browse all Knowledge Base articles below.
How Do You Convert a Non-scheduled MRM Method to a Scheduled MRM Method in Analyst?
Converting a non-scheduled MRM method to a scheduled MRM method requires that the retention time of each transition is updated in the Analyst software method.
Activating Analyst TF 1.7.1 Hardware Profile in Sim Mode
When running Analyst TF 1.7.1 in sim mode on a processing workstation, an additional driver, the Chronologic driver, must be downloaded and installed.
How Is Peak Asymmetry Caluclated in Analyst® Software Quantitate Mode?
Peak asymmetry is calculated in Analyst® software Quantitate mode using the formula((Peak end time) - (Retention Time)) / ((Retention Time - (Peak start time)).
Resetting an Agilent Infinity II LC System after Receiving an ADD Error
This article explains how to reset an Agilent Infinity II LC system after receiving an ADD error by clearing the configuration.
Analyst: How is the limit on the number of samples in the queue increased?
The limit on the number of samples added to the queue for a run can be adjusted using the Max. Num. Waiting Samples setting in the Queue Options menu.
Adjusting Integration Parameters to Exclude Peak Tailing Area in Analyst
Some analytes may display an undesirable amount of peak tailing, some of which may need to be excluded from the total integrated peak area. Adjusting the percent noise parameter in the IntelliQuan dialog may help to decrease the area of the peak included for integration.
What Files Must Be Backed Up before an Analyst Software Reinstall?
Back up the API Instrument project folder in the Analyst Data folder prior to any reinstall or upgrade of the Analyst software. To upgrade an older version of Analyst, remove and back up the Analyst Data folder and any remaining short cuts on your workstation. Reboot the PC and install the new version of the software.
How Is a Special Acquisition Account Setup in Analyst® Software?
To select an Acquisition Account Mode, navigate to the Security Configuration menu in Analyst® software and in the Security tab select the type of account, Client or Special Acquisition Administration Account.
What is the Format of the Login for Analyst Software?
The format of the login for Analyst® software can be in two formats: 1) type in the user name and select the domain from the drop down or 2) log in using user@domain.org or DOMAIN\UserName.
How to adjust, save and export the table settings in an Analyst Quantitation Table
Instructions how to modify (choose and adjust the visible columns, change the significant figures and notation), save and export an Analyst Quantitation Table.
A new password has been sent to your email.
You have added a user.
This serial number could not be found. Would you like to submit the case anyway?
Your password has been updated.
Your account is now created.
A verification link has been sent to your email.
A new password has been sent to your email.
Your insturment has been removed.
Your privacy settings are now updated.
Software has already been registered to another instrument. Please check your AID and try again.
If you want to change the License Key to another instrument, please submit a new case.
Software has already been registered to the instrument selected.
Please check your instrument's software by going to the Instruments page and selecting the instrument in your "My Instruments" section. Here you will see a Software tab where you can view your instrument's software information.
You can also go to the Registered Software page to view software associated with your instrument(s).
If you are not finding what you are looking for, please submit a new case.