The iTRAQ Reagents are the first set of multiplexed, amine-specific, stable-isotope reagents that can label all peptides in up to eight different biological samples enabling simultaneous identification and quantitation, both relative and absolute, while retaining important PTM information. There are two types of iTRAQĀ reagent kits, 4plex and 8plex. The iTRAQĀ Reagents - 8plex kits are also available in more economical bulk packs.
Ā
Innovation in peptide-tagging chemistry
iTRAQĀ®Ā Reagents are an isobaric, peptide-tagging technology that enable you to label all primary amines, regardless of peptide class. Because important information, such as post-translational modifications (PTMs), is retained, this tagging system allows you to extract more detailed information from your samples.
Figure 1:Ā iTRAQĀ®Ā Reagent - 8plex protein quantitation.
Higher-throughput protein biomarker discovery
Obtain protein identification and quantitation simultaneously for up to eight samples for higher throughput biomarker discovery. The straightforward iTRAQĀ®Ā Reagent workflow has less rigorous chromatography demands than non-labeling approaches and provides high-confidence results. And contrary to label-free profiling approaches, iTRAQĀ®Ā Reagents are completely compatible with fractionation strategies that allow you to "dig deeper" and evaluate lower-abundance proteins
Experimental flexibility with confident identifications
The ability to analyze up to eight different samples simultaneously gives you even more experimental-design flexibility. Multiplexing enables you to compare numerous sample states and provides the flexibility to run duplicates and triplicates. MS/MS fragmentation of peptides labeled with iTRAQĀ®Ā Reagents - 8plex results in cleaner spectra with increased signal, giving higher confidence in peptide identifications. And the tagging and analysis of multiple peptides per protein further enhances protein identification.
Figure 2:Ā iTRAQĀ®Ā Reagents - 8plex protein identification.
Solutions for quantitative biology
Whether you are performing relative or absolute quantitation, iTRAQĀ®Ā Reagents - 8plex, MS instrumentation, and application software provide an integrated solution with the ease, flexibility, and confidence in protein quantitation and identification you need for quantitative biology. These reagents are ideal for many applications including pull-downs, membrane protein studies, discovery and validation analysis for biomarker elucidation, and absolute quantitation of target proteins of interest. The reagents are compatible with most mass spectrometers but are optimized for SCIEX instruments.
Kits | Ā |
---|---|
Part Number | Kit Name/Description |
4352135 | iTRAQ Reagents Multiplex Kit Contains iTRAQ reagents 114, 115, 116, 117 (4plex) and the appropriate buffers and reagents for 10 two-plex, 6 three-plex, or 5 four-plex assays. 10-pk trypsin is sold separately. Each individual 1-unit reagent tube has the capacity to label up to 100 ug of protein digest (Note: Recommend using 50 ug of protein digest for plasma and serum). |
4352157 | Trypsin, TPCK treated, 10-Pack A modified (TPCK treated) serine protease that specifically hydrolyzes peptide bonds at the carboxyl side of lysine and arginine residues. Contains calcium chloride which may improve consistency in digestion. Modified trypsin is treated with N-tosyl-L-phenylalanine chloromethyl ketone (TPCK) to inactivate extraneous chymotryptic activity. Each package contains 10 vials containing 25 Āµg in each vial, sufficient for 12 duplex, 8 three-plex, or 6 four-plex when using 100 ug of sample. For serum/plasma experiments we recommend labeling 50 ug of protein per sample (therefore you will need only half as much trypsin). |
4352160 | iTRAQ Reagents Methods Development Kit Contains iTRAQ reagents 114, 117, test sample, buffers and reagents to develop a robust enzymatic digestion and peptide labeling protocol for up to three separate analyses. Each individual reagent is capable of labeling up to 100 ug of protein digest. Included: Starter Kit - Hardware, Cation Exchange Buffer Pack and Cation Exchange Cartridge, Protocol, iTRAQ Reagent Kit. For offline sample prep, please order this together with 4326688, 4326690 and 4326689. No Syringe or tubing is provided by Sciex. |
4369561 | iTRAQ Reagents 3-Assay Duplex Trial Kit Contains iTRAQ Reagents 114 and 117 and the sufficient material to develop a robust protocol and verify that your sample preparation protocol does not interfere with labeling and digestion. Kit contains reagent, reaction solution and test mixture. Cartridges (part number: 4326695) and cation exchange buffer (part number: 4326747) need to be ordered separately. |
4370280 | iTRAQ Reagents Application Kit-Plasma Contains sufficient reaction solutions and iTRAQ Reagents 114, 115, 116 and 117 for 8 duplex or 4 four-plex experiments based on 50 ug of protein per sample. |
4370285 | Trypsin, TPCK treated, 8-Pack A modified (TPCK treated) serine protease that specifically hydrolyzes peptide bonds at the carboxyl side of lysine and arginine residues. Modified trypsin is treated with N-tosyl-L-phenylalanine chloromethyl ketone (TPCK) to inactivate extraneous chymotryptic activity. Each package contains 8 vials containing 25 Āµg in each vial, sufficient for 10 duplex, 6 three-plex, or 5 four-plex when using 100 ug of sample. For serum/plasma experiments we recommend labeling 50 ug of protein per sample (therefore you will need only half as much trypsin). Note: Does not contain calcium chloride. |
4374321 | iTRAQ Reagents Application Kit - Protein Contains sufficient reaction solutions, test mixture and iTRAQ Reagents 114, 115, 116 and 117 (for 25 ug protein) to label 10 duplex, 6 three-plex or 5 four-plex experiments based on 25 ug protein per sample. |
4381664 | iTRAQ Reagent- Multiplex Buffer Kit Includes SDS ā Denaturant, TCEP Reducing Reagent, MMTS cysteine blocking reagent, TEAB buffer and Isopropanol. Enough for 2 multiplex kits. |
4390811 | iTRAQ Reagent-8Plex One Assay Kit Contains iTRAQ Reagents113, 114, 115, 116, 117, 118, 119 and 121 and sufficient material to develop a robust protocol and verify that sample preparation procedures do not interfere with labeling and digestion. Also included are SDS - Denaturant, TCEP Reducing Reagent, MMTS cysteine blocking reagent, TEAB buffer, Isopropanol. |
4390812 | iTRAQ Reagent-8Plex Multiplex Kit Contains iTRAQ Reagents 113, 114, 115, 116, 117, 118, 119 and 121 and sufficient material for five 8plex assays. Each individual 1-unit reagent tube has the capacity to label up to 100 ug of protein digest (Note: Recommend using 50 ug of protein digest for plasma and serum). Multiplex Buffer kit (PN 4381664) sold separately. |
4393528 | iTRAQ Reagent - 8Plex 25 U bulk pack Includes, 8 tubes, each tube contains 25 units of an individual 8plex reagent. |
4393529 | iTRAQ Reagent - 8Plex 50 U bulk pack Includes, 8 tubes, each tube contains 50 units of an individual 8plex reagent. |
4466096 | iTRAQ Reagent - Multiplex 25 U bulk pack Includes, 4 tubes, each tube contains 25 units of an individual 4plex reagent. |
4326688 | Cartridge Holder (need to purchase separately) Cartridge holder to operate cation exchange cartridges and avidin affinity cartridges. |
4326690 | Outlet Connector Outlet tubing used for manual operation of cation exchange. |
4326689 | Needleport Adaptor (need to purchase separately) Used to manually operate the cation exchange. |
4326695 | Cation Exchange (5 pack) Package of five 0.2-ml cation exchange cartridges. Cartridges are operated with cartridge holder (sold separately). |
Is iTRAQ available in bulk?
Yes. Bulk reagent is available in 25 and 50 unit kits of iTRAQ reagents only. You will need approximately one Buffer kit per 10 units.
Why is there a large difference in incubation times between 4-plex and 8-plex iTRAQ?
iTRAQ 8-plex is a different molecule than 4-plex, the reaction time is longer (120 minutes versus 60 minutes)
Are 114 -117 from 4-plex the same as 114 ā 117 of 8-plex?
No, 4-plex and 8-plex are different reagents and should not be combined in an isobaric experiment
Why do I see a different charge state distribution of the target peptides after using iTRAQ?
Because of the different final pH, you may see a difference between the 2+ and 3+ charge states. A shift to more 2+ ions can usually be accomplished by adjusting the pH to 4.0 with 5mM ammonium acetate
Can I re-use the iTRAQ reagent after the vial has been opened?
No. Each vial of iTRAQ reagent is filled and capped under inert gas. The reagent is easily degraded by moisture leading to poor subsequent labeling efficiency. In the case of bulk reagent kits, there is a specific protocol to follow for aliquoting and storage.
My iTRAQ solution seems to be a different colour, is it OK?
Probably. The colour of the iTRAQ reagent can vary slightly depending on many factors ranging from trace metals to moisture. The reagent performance is typically unaffected.
How much protein can I label?
Each vial of 8-plex reagent contains 2 Āµmol of iTRAQ reagent. This is usually sufficient to label 20-100 Āµg of protein digest. For plasma and serum samples which contain many non-peptide primary amine compounds, the protocol may need to be adjusted. Important elements include buffering to pH 7.5 to 8.5, buffer concentration between 90 ā 100 mM, iTRAQ reagent concentration at 40 mM (Ā±5%), and total organic concentration greater than 65%
How long can I store sample after labelling?
we recommend you label only when you are going to analyze the samples immediately, please do not store your labelled samples for longer than two weeks.