Save time, save money, stay compliant – and be confident that your mass spectrometer is performing at its best.

MS calibration kits

For research use only. Not for use in diagnostic procedures.

We provide mass spectrometry performance calibrants and standards kits to ensure your mass spectrometer is turned for optimal performance and delivers reproducible results.
 

  • Optimized for SCIEX instrumentation
  • Ensure data consistency – avoid risking the integrity of your workflow
  • Save time and resources
  • Maintain peak performance – troubleshoot your mass spectrometer in minutes
  • Qualify your instrument for IQ/OQ/PQ – any day, any time

Community Discussions

Status: Available

Overview

The MS calibration kits contain reagents for calibration, tuning, and optimization for all LC-MS/MS instruments and SCIEX Triple Quad, QTRAP, TripleTOF, QTOF and ZenoTOF systems.

Part numberKit name/ InstrumentDescription
4465867LC-MS Peptide Calibration kit (Replaces kit #4368624)Calibration kit for evaluation of MS and MS/MS during electrospray infusion using Glu-fibrinogen peptide, and evaluation of LC-MS/MS mode using tryptic digest beta-galactosidase.

Kit contains two tubes of beta galactosidase digest (625 pmol/vial), one tube of glu-fibrinogen peptide and two bottles of standard diluent.  This kit replaces the LC-MS Peptide/Protein Mass Standards kit (part #4368624)
4465938Beta-Galactosidase, DigestedKit contains one vial of beta galactosidase digest (625 pmol/vial)

MS calibration kits for Triple Quad instruments

Part numberKit name/ InstrumentDescription

5077206

MS Single Tuning Solution

Kit includes one tube of MS Single Tuning Solution (25mL) and one MS Wash Solvent ( 25mL). Calibration kit for SCIEX Triple Quad 7500 system - QTRAP Ready.

 

4406127MS Chemical kit 1, low-high conc. PPGsStandards chemical kit with low/high concentrations of polypropylene glycol polymers (PPGs).

This kit includes all solutions necessary for installation and calibration for all SCIEX Triple Quads, excluding the API 2000 and API 3000 series.
4412399MS Chemical kit 2, higher conc. PPGsStandards chemical kit with high concentrations PPGs.

This kit includes all solutions necessary for installation and calibration for all API 2000 and API 3000 series instruments.
4465788SelexION Calibration solutionInstallation and Calibration Solution for SelexION differential mobility spectrometry (DMS)

MS calibration kits for X500 instruments

Part numberKit name/ InstrumentDescription

5077206

MS Single Tuning Solution

Kit includes one tube of MS Single Tuning Solution (25mL) and one MS Wash Solvent ( 25mL). Calibration kit for SCIEX Triple Quad 7500 system - QTRAP Ready.

 

4406127MS Chemical kit 1, low-high conc. PPGsStandards chemical kit with low/high concentrations of polypropylene glycol polymers (PPGs).

This kit includes all solutions necessary for installation and calibration for all SCIEX Triple Quads, excluding the API 2000 and API 3000 series.
4412399MS Chemical kit 2, higher conc. PPGsStandards chemical kit with high concentrations PPGs.

This kit includes all solutions necessary for installation and calibration for all API 2000 and API 3000 series instruments.
4465788SelexION Calibration solutionInstallation and Calibration Solution for SelexION differential mobility spectrometry (DMS)

MS calibration kits for TripleTOF instruments

There are four calibration solution types available, APCI Positive, APCI Negative, ESI Positive and ESI Negative. Chose a calibrant that reflects the type of ionization mode used for sample analysis. If using ESI for sample ionization, an APCI calibration solution is needed. If using APCI for sample ionization, then chose an ESI calibration solution.

Part numberKit name/ InstrumentDescription
4465920Tuning SolutionKit used for resolution and sensitivity of the TOF high mass and MS/MS high mass in positive mode.  Kit contains a bottle of tuning solution formulated with CSL and a peptide.  This is identical to the tuning solution found in installation kit for SCIEX TripleTOF system (part #4456736).
4460131APCI Positive Calibration Solution 5600This calibration solution for the TripleTOF 5600 system is intended for positive ion mode with the DuoSpray source. Calibration solution is introduced using the atmospheric-pressure chemical ionization (APCI) probe; sample analysis is with electrospray ionization (ESI) probe.
4460134APCI Negative Calibration Solution 5600This calibration solution for the TripleTOF 5600 system is intended for negative ion mode with the DuoSpray source. Calibration solution is introduced using the APCI probe; sample analysis is with ESI probe.
4460136APCI Positive Calibration Solution 5600 5pkThis calibration solution (five pack) for the TripleTOF 5600 system is intended for use in positive ion mode with the DuoSpray source. Calibration solution is introduced using the APCI probe; sample analysis is with the ESI probe.
4460138APCI Negative Calibration Solution 5600 – 5 packThe calibration solution (five pack) for the TripleTOF 5600 system is intended for use in negative ion mode with the DuoSpray source. The calibration solution is introduced using the APCI probe; sample analysis is with the ESI probe.
4463272ESI Positive Calibration Solution 5600The calibration solution for the TripleTOF 5600 system is intended for use in positive ion mode with the DuoSpray source. The calibration solution is introduced using the ESI probe; sample analysis is with the APCI probe.
4463274ESI Positive Calibration Solution 5600 – 5 packThe calibration solution (five pack) for the TripleTOF 5600 system is intended for use in positive ion mode with the DuoSpray source. The calibration solution is introduced using the ESI probe; sample analysis is with the APCI probe.
4463276ESI Negative Calibration Solution 5600 – 5 packThe calibration solution (five pack) for the TripleTOF 5600 system is intended for use in negative ion mode with the DuoSpray source. The calibration solution is introduced using the ESI probe; sample analysis is with the APCI probe.
4463277ESI Negative Calibration Solution 5600The calibration solution for the TripleTOF 5600 system is intended for use in negative ion mode with the DuoSpray source.  The calibration solution is introduced using the ESI probe; sample analysis is with the APCI probe.
4456736Installation kit for SCIEX TripleTOF 5600 systemKit used for installation of the 5600 family of instruments