Streamline and simplify your workflows, delivering more and faster with software engineered for all your SCIEX mass spectrometry systems.
Streamline and simplify your workflows, delivering more and faster with software engineered for all your SCIEX mass spectrometry systems.
SCIEX OS software is faster than previous operating systems. The time between sample injections is reduced to just a couple of seconds. Over the duration of a large batch the time saving is vast, consider that over a week, month or a year. SCIEX OS software will improve your analytical throughput.
1. Acquire and process SCIEX Triple Quad and QTRAP scans
2. Zeno SWATH DIA integration
SCIEX OS software is faster than previous operating systems. The time between sample injections is reduced to just a couple of seconds. Over the duration of a large batch the time saving is vast, consider that over a week, month or a year. SCIEX OS software will improve your analytical throughput.
3. Custom Calculations & Flagging Rules
4. Molecule Profiler, Biologics Explorer and MarkerView software integration
5. Enhanced tuning tools for SCIEX Triple Quad and QTRAP systems
Version feature matrix
View a list of all the features that were added to each version of SCIEX OS software.
Advantages of SCIEX OS software
Discover the capabilities you gain when you upgrade from Analyst software
Discover essential steps and expert tips for a smooth transition to SCIEX OS software. This guide will help ensure your data integrity and streamline your lab operations effortlessly.
Facilitates quick batch setup, streamlining your workflow and saving you valuable time.
Visualize your acquired data including total ion and extracted ion chromatograms.
This is where you enter details about your samples, including the mass spectrometry and liquid chromatography methods and the autosampler values, such as rack position, plate type, vial position and sample injection volume. You can also indicate the processing method to use and where to save the results file in the directory. Building a batch is simple and straightforward, and any existing Analyst software methods can be directly imported into SCIEX OS software.
Other features available in the Batch workspace include auto-calibrate functionality, which enables accurate mass systems to select the right type of calibration solution for your method and the plate layout of the autosampler rack. Previously saved batches can also be reopened, and the Manage tab can be used for adding rows to your batch. When your details are entered, the batch is ready to go and you can hit submit.
After you hit submit in the Batch workspace, you can view the progress of your analysis in the Queue workspace. The acquisition status is displayed, so you can quickly see that your samples are running smoothly. The estimated start time allows you to forecast when the analysis will be complete.
The Queue workspace displays many of the same details from the Batch workspace, such as MS and LC methods. You have the power to start and stop the queue from here, should you wish to make changes to your batch.
Decision rules functionality allows for immediate detection of failures and implementation of corrective action based on criteria that you establish. This non-subjective decision making adapts to changing conditions during analysis. The decision rules functionality continually checks against customized criteria. With decision rules, you don't have to wait for acquisition, data processing and data review to discover failures and take action.
SCIEX OS software enables you to build separate liquid chromatography methods. The information displayed in the LC Method workspace will depend on the LC configuration you select for your analysis. Here, you can input all the details regarding flow rates, autosampler conditions, column oven temperature controls and potential wavelength data for photodiode array detector (PDA) wavelengths. You can also adjust any other settings you may need, such as executing an auto-purge before analysis.
The Tuning Procedures drop-down menu shows specific options for you instrument. You can use the detector optimization tool to optimize the detector voltage if you notice the sensitivity of the system seems low.
SCIEX OS software enables automated tuning for the SCIEX Triple Quad 7500 system and the X500 series QTOF systems by calibrating all scans across all modes for added confidence that your system is ready to use with fast, easy and simple tuning.
Your instrument will be calibrated correctly with built-in acceptance criteria for a higher first-time success rate, saving you a significant amount of time.
A single calibrant for both positive and negative mode means:
In the MS Method workspace, you can create a standard MRM or MRMHR method, depending on whether you are operating a SCIEX Triple Quad system or an accurate mass instrument. If you are running a SCIEX accurate mass instrument, you might want to create a SWATH acquisition method. Guided method creators are available to assist you in developing new methods for new analytes you want to analyze.
Source parameters (such as source gases, curtain gas and temperature settings) for the Turbo V ion source and the OptiFlow Pro ion source can be configured here.
The Experiment section is for selecting the type of experiment to run, such as TOF MS, MRM and MRMHR. You can select multiple experiments for your analysis, so your system can acquire even more data for you.
Whether it's an infusion, flow injection, on-column or MRM3 approach, the automated compound optimization feature for quantification is simple, flexible and completely automated. There are also options for choosing optimal parameters such as signal-to-noise (S/N) ratio or intensity requirements.
Scheduled MRM (sMRM) helps drive the accuracy and precision of your mass spectrometer. sMRM accounts for any potential retention time (RT) drifts, and all RTs can be updated with a single click. sMRM also has functionality to call out single dwell time instances so you can maximize the abundance of low-intensity ions. In addition, interactive sMRM plots dynamically update with any changes in the sMRM method.
Leveraging the latest acquisition techniques and built on a heritage of proven performance, Biologics Explorer software delivers highly accurate and informative workflows for fully characterizing protein biotherapeutics.
A data visualization tool designed for scientists who wish to visualize their data in terms of sample groupings and apply statistics in order to gain valuable insight into any trends within their mass spectral data. MarkerView is unique in that SCIEX users can explore statistical correlations with direct connections back to the raw data. This allows them to find meaningful relationships much more quickly. Particularly useful for metabolomics, lipidomics, proteomics, food authenticity and water testing.
The navigation tools in the Explorer workspace allow you to quickly move through the samples for an overview of your data. You can view the data in several ways depending on your preference.
Spend less time digging for answers. Only review data of interest with flag-based labelling and filtering tools.
1. Peak Integration
Increase performance with the powerful AutoPeak integration algorithm for more reliable integration across samples, batches and analytes. This will allow you to achieve reliable peak integration with ease, even with low-level peaks and complex matrices. No manual intervention is needed to re-integrate peaks, remove interferences or adjust retention time.
2. Workspace layouts
In a high-throughput lab environment that requires consistency and the continued delivery of high-quality data, you need a layout for your analysis that is familiar and enables you to interpret data faster. Custom workspaces can now be saved.
3. Automatic outlier removal
Simplify calibration curve review.
4. Calculated columns and flagging rules
SCIEX OS software has the ability to support “IF” statements for your analysis queries. There is functionality to execute calculations within the “IF” statement. “IF” statements can be built into the flagging rules when the outcome is a numeric value. Some of the data analysis you wish to conduct may be complex, therefore there is no limitation on the formula size of your query. Nested “IF” statements are also supported, and they can be packaged into a .frml file format and shared.
Driven by MS and MS/MS data analysis coupled with extensive libraries, Molecule Profiler software delivers highly accurate and flexible workflows for determining impurities and biotransformations for a wide variety of therapeutic molecules.
Molecule Profiler is fully integrated as part of SCIEX OS, and has the same look and feel. Easily multitask with other functions in SCIEX OS. And, there is no need to move data around.
The Configuration workspace also provides the ability to add devices you may need or edit the configuration of your instruments. Within the workspace, you can adjust settings for queue management, such as maximum idle time allowed before the system goes into standby and the maximum number of samples allowed. There are also rule settings that advise users on what to do when a sample is missing, for example. If you are operating one of the X500 series QTOF instruments, you can specify calibration settings and what the system should do if there is a calibration failure.
From compliant routine analyses to flexible research workflows, the intuitive Audit Trail workspace ensures full traceability and accountability. It includes built-in data integrity features that allow you to tailor each functionality specifically to your lab's compliance and data security requirements.
SCIEX integrated compliance services include integrated analytical instrument qualification and software validation packages that cover your complete SCIEX system workflow.
The Library workspace is used to import a library that you would like to use as part of your workflow. Libraries provide additional confirmation and assurances for confirm your data acquisitions. You can import a LibraryView software package or your own custom library.
During this process, you can select which compounds you would like to include in your processing. You may want to include every compound in the SCIEX All-in-One HR-MS/MS library, for instance, or just extract the compounds that are crucial to your experiment.
The Event Log workspace shows you useful diagnostic information and events happening within SCIEX OS software. Within this workspace, you can archive a log at your specific intervals. You can also open previously archived event logs here, so you can dig into any of the information that may be of use.
Transform your research and experience seamless integration, enhanced usability, and robust data management in every analysis.
Enhanced efficiency
Boost your lab's output with SCIEX OS software. Simplify your mass spectrometry workflows to consistently produce high-quality, actionable data.
Improved usability
Unify operations across all SCIEX instruments using our intuitive software interface. Tailor your data review and processing with our adaptable API integration.
Unmatched data integrity
Trust in the exceptional accuracy and stability of SCIEX OS software to safeguard data quality across every analysis, ensuring consistent results batch after batch.
Streamlined automation
Automate your data processing to minimize errors and allocate resources to more critical tasks, enhancing productivity and reliability.
Collaborate with global teams
Communicate globally across different timezones by translating the user interface in your preferred language (Chinese, Japanese, Korean, German, Italian, French, Spanish, Portuguese and English).
Operational savings
Explore how you can expand your productivity and save money simultaneously.
Control, manage and audit
Laboratories with multiple instruments can now use the Central Administrator Console (CAC) on SCIEX OS software 3.0 or later to create and manage projects.
Define and set appropriate permissions for your staff as an administrator role, method developer, analysts or a reviewer. Create individual accessibility rules or assign to a workgroup.
The versatility of SCIEX instruments enables you to run lots of varying experiment types. The CAC allows you to organize, collate and prioritize the projects and assign root directories.
A comprehensive audit configuration setup specifically for CAC enables users to set full traceability on the console workstation including reasons, e-signatures and timestamped event logs. User profiles and permissions can be printed out for easier compliance submission.
SCIEX OS software is the complete software platform for the SCIEX Triple Quad 7500+, 7500, 6500+ series, 5500+ series and 4500 systems. With its automated tools simplifying peak finding and integration, and calibration curve review, SCIEX OS software helps you reach new levels of precision across all your quantitative workflows.
SCIEX OS software powers up all targeted, non-targeted and suspect screening workflows analyzed with your SCIEX QTRAP, ZenoTOF, TripleTOF and X500 QTOF series instruments. Automated custom flagging and filtering tools enable rapid data review and real-time decision making. All with high levels of confidence.
The Intabio ZT system couples icIEF separation and UV detection with high-resolution mass spectrometry on the ZenoTOF 7600 system. Experience one integrated workflow with a single, accessible dataset containing the required information to make the right decisions, fast.
Achieve the balance of unyielding data quality, speed and cost for high-throughput screening workflow.
Incorporate electronic audit trails, electronic signatures and detailed security configurations to support GxP and 21 CFR Part 11 regulations. SCIEX OS software offers the flexibility to tailor and deploy security policies that help you meet the requirements of your laboratory.
Specification | Workstation requirements | CAC server requirements |
---|---|---|
Operating system | Windows 7 (64-bit), Windows 10 (64-bit), version 1809 LTSC, 20H2, or 21H2. English, French, German, and Italian operating systems are supported | Windows 10 (64-bit), version 1809 LTSC. 20H2, or 21H2; Windows Server 2019 and later. English operating system only |
Processor | Intel Xeon W3-2435 22.5MB 8 cores 3.1GHZ to 4.5GHZ | Multicore processor (with 64-bit support), 3 GHz |
RAM | 32GB DDR5 4800MHZ | 8 GB, 32 GB recommended |
Data storage | 2 x 1TB Raid 1, NVMe SSD Class 40 (for TOF products 2 x 2TB) | 1 TB SSD minimum |
Graphics card | NVIDIA T400 4GB | N/A |
As laboratory infrastructure becomes interconnected, software APIs are a key component to enabling this connectivity. SCIEX offers 3 APIs that provide connectivity to SCIEX OS software and data.
A client library that enables remote control of SCIEX OS software from external applications. Using the control API, the user can control and monitor the data acquisition-related activities of the mass spectrometer. Tasks that can be performed with the control API include:
The processing API provides a set of software tools to process and read data acquired by SCIEX OS software.
A set of software tools that allows software developers to extract information from SCIEX OS software wiff2 data files. This information can then be used in third-party processing applications. The data API can access the following types of data:
SCIEX OS software is developed using security-by-design and defense-in-depth principles built into the product development process. It is analyzed with industry-recognized automation analysis tools to discover security vulnerabilities in both source code and third-party components. The configuration of SCIEX OS software is hardened against standardized security policies using industry best practices. Additionally, it is developed using secure coding standards by developers who complete mandatory annual secure code training.
Existing users of SCIEX OS software can download the latest updates here.
Join an inclusive community that welcomes all voices and viewpoints. Help shape the future of innovation and science for everyone.
Here is a link to all the relevant end-user licence agreements for your version of SCIEX OS software.
Rely on our expert scientists and workflow enhancement specialists to guide and collaborate with you to maximize your results.
SCIEX OS software tips
The Automatic Outlier Removal feature in SCIEX OS software can significantly reduce calibration curve review time. The algorithm allows the user to set criteria including regression linearity, accuracy of standards, precision of replicates and acceptable outlier tolerance for the automatic removal of standard outliers from the calibration curve in the processing method. This feature helps alleviate the pain of manually establishing many calibration curves when working with many analytes that vary in sensitivity and performance, and it represents a leap forward in time savings for data reviewers.